Applications · 14 equipment groups

O-Ring Applications

Start from the machine, seal position and service conditions—not the industry name. Use these routes to decide what must be known before material, size, hardness or purchasing.

By equipment

Choose by equipment and seal position

Each card opens the application guide where one is published, or sends the details for an engineering review.

Full guide

Hydraulic

RodPistonStatic fittingBackup ring

Rod, piston or static fitting? Separate motion and seal position, then add fluid, temperature, pressure cycle and geometry.

Open Hydraulic
Guide

Pumps

Separate static housing and cover joints from rotating shaft boundaries. Do not assume an O-ring is the primary shaft seal.

Open Pumps
Guide

Valves

Split stem, seat and body/bonnet locations. Oscillating stems, seat closure and static body joints need different checks.

Open Valves
Guide

Automotive & Fuel

Identify gasoline, diesel, alcohol blend, engine oil or ATF before screening material; “fuel resistant” is not one condition.

Open Automotive & Fuel

Water Systems

Separate potable water, chlorine/chloramine service, filtration, seawater and pump conditions; approvals stay compound-specific.

Send a water-system RFQ

Food & Pharma

Check product contact and CIP/SIP exposure separately, then verify exact compound/product documentation.

Send a food/pharma RFQ

Semiconductor & Vacuum

Treat leakage, permeation, outgassing, plasma chemistry, wet chemistry and purity as separate engineering questions.

Send a semiconductor/vacuum RFQ

AI Liquid Cooling

Cold plates, manifolds, quick disconnects and coolant loops are under engineering review. Start with the exact coolant formulation and interface geometry.

Send a liquid-cooling RFQ

Engine & Powertrain

Cooling, lubrication, crankcase/cylinder-head and drivetrain routes built from verified service/application evidence.

Send an engine RFQ

Coffee & Espresso

Brew, automatic-machine, boiler, portafilter and steam/hot-water sealing routes.

Send a coffee-machine RFQ

Pneumatic Tools

Internal air sealing, nailer/stapler assemblies and repair-kit routes.

Send a pneumatic-tool RFQ

Water Softener & Plumbing

Control, faucet, spout, cartridge and watering-connector sealing routes.

Send a plumbing RFQ

Appliance & Cleaning

Dishwasher, cleaning-equipment, hose, wand and connector sealing routes.

Send an appliance RFQ

HVAC & Refrigeration

Compressor, refrigerant-line, condenser/evaporator and refrigeration sealing routes.

Send an HVAC RFQ

Equipment not listed?

Start from what you already know: the fluid, the size, the failed seal or the groove.

Choose by what you know

Workflow

Use the tools in the right order

  1. 01Choose the application route and exact seal position. Equipment routes
  2. 02Screen the material against the actual media, temperature and service mode. Chemical check
  3. 03Confirm geometry and dimensions; use Engineer Pro only for supported modes. Engineer Pro
  4. 04Use the Finder after size, material and hardness are resolved. Open Finder
  5. 05Use RFQ when geometry, compound, documentation or service conditions remain uncertain. Request engineering review

Evidence boundaries

  • Material family is screening. NBR, FKM, EPDM, Silicone, FFKM and other family names do not by themselves approve a compound for a specific fluid, pressure, temperature or machine.
  • Catalog match is not stock or approval. The Finder confirms a catalog configuration route. Inventory, application suitability and documentation are separate checks.
  • Compliance belongs to exact evidence. FDA, NSF, USP, 3-A or other claims must map to the exact product/compound and valid document scope.

Next step

Know the size? Start from the common ones

Most equipment uses standard AS568 or metric sizes. Pick one to see every listed material and hardness, or search your exact ID × CS.

FAQ

Frequently asked questions

Not sure which route fits? Send the machine, seal position, media, temperature and pressure for a review.

Request an engineering review
Where should I start if I only know the equipment?
Choose the closest application cluster, then identify the exact O-ring location and whether it is static or moving.
Where should I start if I only know the fluid?
Use Chemical Compatibility as a first screen, then add temperature, motion, geometry and exact compound evidence before ordering.
Can the Finder tell me which O-ring is safe for my machine?
The Finder can match real size/material/hardness configurations, but it does not replace engineering or chemical-compatibility review.
Why are some applications routed to RFQ instead of a calculator?
Some geometries or service modes are outside the supported Engineer Pro models, or the exact compound/document requirement is unresolved.
Why is AI liquid cooling routed to engineering review?
The current AI-cooling pages are still held from publication while coolant-specific and product-level evidence is completed; the RFQ route avoids creating a public dead link or an unsupported material recommendation.